Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
1.
J Dent ; 144: 104963, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522636

RESUMO

OBJECTIVE: To investigate the association of perforation of the maxillary sinus floor by dental implants with mucosal thickening and to describe its characteristics in perforated cases. STUDY DESIGN: One-hundred and twenty-nine maxillary sinuses of 93 patients presenting 202 dental implants in the maxillary posterior region were retrospectively assessed in cone-beam computed tomography scans and classified according to maxillary sinus perforation, bone graft, mucosal thickening, and mucosal appearance. Logistic regression determined the chance of mucosal thickening in perforated maxillary sinuses. The chi-square test compared categorical variables between maxillary sinus perforated or not by implants and maxillary sinus with or without mucosal thickening. The significance level assumed was 5 % (α = 0.05). RESULTS: There was perforation of 60 maxillary sinuses floor (46.5 %) by 74 dental implants. The chance of mucosal thickening was higher when the implant tip was trespassing on the maxillary sinus floor (p < 0.001). There was a significant association between maxillary sinus mucosal thickening and perforation by a dental implant with the tip trespassing the maxillary sinus floor (p < 0.05). CONCLUSION: Maxillary sinus mucosal thickening is associated with sinus floor perforation by dental implants and does not depend on the number of implants perforating it. CLINICAL RELEVANCE: There is an association between dental implants' perforation of the maxillary sinus floor and the thickening of the maxillary sinus. In those cases, the appearance of the mucosa thickening may be irregular, local, or total opacification of the sinus cavity.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Seio Maxilar , Humanos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Implantes Dentários/efeitos adversos , Idoso , Adulto , Mucosa Nasal/diagnóstico por imagem , Mucosa Nasal/lesões , Mucosa Nasal/patologia , Transplante Ósseo , Idoso de 80 Anos ou mais
2.
Braz Oral Res ; 37: e132, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38126475

RESUMO

This crossover study aimed to compare the anesthetic effects of buffered 2% articaine with 1:200,000 epinephrine with that of non-buffered 4% articaine with 1:200,000 epinephrine. Forty-seven volunteers were administered two doses of anesthesia in the buccal region of the second mandibular molars in two sessions using 1.8 mL of different local anesthetic solutions. The onset time and duration of pulp anesthesia, soft tissue pressure pain threshold, and the score of pain on puncture and burning during injection were evaluated. The operator, volunteers, and statistician were blinded. There were no significant differences in the parameters: onset of soft tissue anesthesia (p = 0.80), duration of soft tissue anesthesia (p = 0.10), onset of pulpal anesthesia in the second (p = 0.28) and first molars (p = 0.45), duration of pulp anesthesia of the second (p = 0.60) and first molars (p = 0.30), pain during puncture (p = 0.82) and injection (p = 0.80). No significant adverse events were observed. Buffered 2% articaine with 1:200,000 epinephrine did not differ from non-buffered 4% articaine with 1:200,000 epinephrine considering anesthetic success, safety, onset, duration of anesthesia, and pain on injection.


Assuntos
Carticaína , Lidocaína , Humanos , Carticaína/farmacologia , Lidocaína/farmacologia , Estudos Cross-Over , Anestésicos Locais/farmacologia , Epinefrina/farmacologia , Anestesia Local , Dor , Dente Molar , Método Duplo-Cego
3.
J Stomatol Oral Maxillofac Surg ; 124(6S2): 101657, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37866505

RESUMO

OBJECTIVE: This cross-sectional study aimed to evaluate the presence of bone changes on magnetic resonance imaging (MRI) scans of patients with temporomandibular joint (TMJ) anterior disc displacement (ADD) with reduction (ADDWR) and without reduction (ADDWoR). METHODS: TMJ-MRI scans were screened for the presence of ADD. 285 scans presented ADD, being further divided into ADDWR (n = 188) and ADDWoR (n = 97). Bone changes on the mandibular condyle and articular eminence were also assessed and computed. The chi-square test compared the association of these bone changes with the presence of ADDWR and ADDWoR, with a significance level of 5 %. Also, the prevalence ratio (PR) was calculated. RESULTS: In the mandibular condyle, subchondral cyst (p = 0.035, PR = 1.08) and bone edema (p = 0.044, PR = 2.40), more prevalent on ADDWR, and generalized sclerosis (p = 0.015, PR = 1.04), more prevalent on ADDWoR, presented significant association with ADD. On the articular eminence, generalized sclerosis (p = 0.015, PR = 1.04) and articular surface flattening (p = 0.003, PR = 1.19) presented significant association with ADD, both more prevalent on ADDWoR. CONCLUSION: Bone changes are usual findings in TMJ with ADD diagnosis. The real influence of ADD is not fully clear, although clinicians should be aware of patients with this condition, to provide an early diagnosis and improve patient´s prognosis.


Assuntos
Transtornos da Articulação Temporomandibular , Articulação Temporomandibular , Humanos , Estudos Transversais , Esclerose/patologia , Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/epidemiologia , Imageamento por Ressonância Magnética
4.
Sci Rep ; 13(1): 10819, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37402784

RESUMO

Accurate mandibular canal (MC) detection is crucial to avoid nerve injury during surgical procedures. Moreover, the anatomic complexity of the interforaminal region requires a precise delineation of anatomical variations such as the anterior loop (AL). Therefore, CBCT-based presurgical planning is recommended, even though anatomical variations and lack of MC cortication make canal delineation challenging. To overcome these limitations, artificial intelligence (AI) may aid presurgical MC delineation. In the present study, we aim to train and validate an AI-driven tool capable of performing accurate segmentation of the MC even in the presence of anatomical variation such as AL. Results achieved high accuracy metrics, with 0.997 of global accuracy for both MC with and without AL. The anterior and middle sections of the MC, where most surgical interventions are performed, presented the most accurate segmentation compared to the posterior section. The AI-driven tool provided accurate segmentation of the mandibular canal, even in the presence of anatomical variation such as an anterior loop. Thus, the presently validated dedicated AI tool may aid clinicians in automating the segmentation of neurovascular canals and their anatomical variations. It may significantly contribute to presurgical planning for dental implant placement, especially in the interforaminal region.


Assuntos
Aprendizado Profundo , Canal Mandibular , Mandíbula/cirurgia , Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico
5.
Artigo em Inglês | MEDLINE | ID: mdl-37468379

RESUMO

OBJECTIVE: The aim of this study was to evaluate the influence of binarization methods (BnMs) on the fractal dimension (FD) of the alveolar bone in digital radiographic images. STUDY DESIGN: Five identical periapical radiographs were obtained from each of 20 anatomic regions. Using ImageJ/Fiji software, a standardized region of interest was positioned in the trabecular bone of all radiographs, 14 BnMs were independently applied, and FD was calculated. The Friedman test and Dunn post hoc tests were used to evaluate the influence of BnMs on FD (α = 0.05). The intraclass correlation coefficient (ICC) was used to assess correlation among BnMs. RESULTS: No significant differences were observed in the threshold value between the BnMs. No significant differences in FD were observed among 9 BnMs (Default, Huang, Iso Data, Li, Mean, Min Error[I], Moments, Otsu, and Shanbhag). These methods presented significantly higher FDs than those from 3 other BnMs (Max Entropy, Renyi Entropy, and Yen), which did not significantly differ from each other. The Triangle method significantly differed from all BnMs, and the Percentile method produced significantly higher FDs than Huang, IsoData, Li, Moments, Otsu, and Shanbhag. Most BnMs presented good or excellent correlation (ICC ≥ 0.76). CONCLUSIONS: Binarization methods influence FD of the alveolar bone from digital periapical radiographs; thus, this technical aspect is relevant for comparison purposes and should be standardized. For comparison of published FD research, the Default method is recommended.


Assuntos
Fractais , Mandíbula , Humanos , Radiografia Dentária Digital/métodos , Radiografia , Osso Esponjoso
6.
Braz Dent J ; 34(1): 39-44, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36888843

RESUMO

The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Assuntos
Radiografia Dentária Digital , Radiografia Dentária Digital/métodos , Reprodutibilidade dos Testes
7.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420574

RESUMO

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

8.
Artigo em Inglês | MEDLINE | ID: mdl-36566136

RESUMO

OBJECTIVE: The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN: Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS: The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS: The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.


Assuntos
Cárie Dentária , Radiografia Interproximal , Humanos , Cárie Dentária/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Dente Molar/patologia , Sensibilidade e Especificidade
9.
Braz. oral res. (Online) ; 37: e132, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528132

RESUMO

Abstract This crossover study aimed to compare the anesthetic effects of buffered 2% articaine with 1:200,000 epinephrine with that of non-buffered 4% articaine with 1:200,000 epinephrine. Forty-seven volunteers were administered two doses of anesthesia in the buccal region of the second mandibular molars in two sessions using 1.8 mL of different local anesthetic solutions. The onset time and duration of pulp anesthesia, soft tissue pressure pain threshold, and the score of pain on puncture and burning during injection were evaluated. The operator, volunteers, and statistician were blinded. There were no significant differences in the parameters: onset of soft tissue anesthesia (p = 0.80), duration of soft tissue anesthesia (p = 0.10), onset of pulpal anesthesia in the second (p = 0.28) and first molars (p = 0.45), duration of pulp anesthesia of the second (p = 0.60) and first molars (p = 0.30), pain during puncture (p = 0.82) and injection (p = 0.80). No significant adverse events were observed. Buffered 2% articaine with 1:200,000 epinephrine did not differ from non-buffered 4% articaine with 1:200,000 epinephrine considering anesthetic success, safety, onset, duration of anesthesia, and pain on injection.

10.
Artigo em Inglês | MEDLINE | ID: mdl-36361338

RESUMO

We evaluated the influence of population size (POP), HDI (Human Development Index) and GDP (gross domestic product) on the COVID-19 pandemic in the Southeast region of Brazil, between February 2020 and May 2021. METHODS: Cases, deaths, incidence coefficient, mortality rate and lethality rate were compared among states. The cities were divided into strata according to POP, GDP, and HDI. Data were compared by Welch's ANOVA, nonlinear polynomial regression, and Spearman's correlation test (rS). RESULTS: The highest incidence coefficient (p < 0.0001) and mortality rate (p < 0.05) were observed in the states of Espírito Santo and Rio de Janeiro, respectively. Until the 45th week, the higher the POP, the higher the mortality rate (p < 0.01), with no differences in the remaining period (p > 0.05). There was a strong positive correlation between POP size and the number of cases (rS = 0.92, p < 0.0001) and deaths (rS = 0.88, p < 0.0001). The incidence coefficient and mortality rate were lower (p < 0.0001) for low GDP cities. Both coefficients were higher in high- and very high HDI cities (p < 0.0001). The lethality rate was higher in the state of Rio de Janeiro (p < 0.0001), in large cities (p < 0.0001), in cities with medium GDP (p < 0.0001), and in those with high HDI (p < 0.05). CONCLUSIONS: Both incidence and mortality were affected by time, with minimal influence of POP, GDP and HDI.


Assuntos
COVID-19 , Humanos , Produto Interno Bruto , COVID-19/epidemiologia , Densidade Demográfica , Brasil/epidemiologia , Pandemias
11.
Photodiagnosis Photodyn Ther ; 40: 103123, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36115559

RESUMO

OBJECTIVE: To evaluate the efficacy of methylene blue (MB)-mediated antimicrobial photodynamic therapy (aPDT) doped with potassium iodide (KI) against oral microcosms biofilms cultured in dentin. METHODS: A saliva-glycerol stock formed from pooled human saliva was diluted in McBain artificial saliva with 1% sucrose (1:1), inoculated on bovine dentin blocks, and refreshed daily for 5 days. The biofilms were divided (n = 9/group) and treated with 0.9% NaCl (C), 0.2% chlorhexidine (CX), 0.01% MB + low-power laser 15 J, 88 mW, 180 s (PL), and 0.01% MB + 50 mM KI + laser (PKIL). Serial dilution was performed, and cellular viability (CFU/mL) was evaluated for total microorganisms, total lactobacilli, total streptococci, and S. mutans. Additional biofilms were cultured and treated (n = 4) for biomass determination (%BMR). The microscopic structure of the biofilms was observed by SEM. One-way ANOVA and Tukey tests were conducted (α=5%). RESULTS: Total microorganisms and total streptococci significantly reduced in biofilms treated with CX and PKIL when compared to C, but the CX, PKIL, and PL treatments did not differ from each other. Total lactobacilli and S. mutans showed a significant reduction in the CX, PL, and PKIL groups when compared to C, but with no difference between them. Biomass analysis showed a significantly reduction for CX and PKIL compared to C. SEM micrographs showed noticeable changes in bacterial membrane integrity for the PKIL and CX groups. CONCLUSION: The addition of KI to methylene blue-mediated aPDT in microcosm biofilms was effective in reducing oral microorganisms, but the effect was group dependent.


Assuntos
Anti-Infecciosos , Fotoquimioterapia , Bovinos , Animais , Humanos , Fotoquimioterapia/métodos , Azul de Metileno/farmacologia , Iodeto de Potássio , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico , Streptococcus mutans , Biofilmes , Anti-Infecciosos/uso terapêutico , Streptococcus , Clorexidina/farmacologia , Lasers
12.
J Dent Anesth Pain Med ; 22(3): 227-231, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35693352

RESUMO

Although rare, complications can occur with anesthetic procedures. The posterior superior alveolar nerve (PSAN) block anesthetic technique has a high success rate, but positive aspiration can cause bruising, transient diplopia, blurred vision, and temporary blindness in approximately 3% cases. When edema occurs, it is occasionally massive, especially in the infratemporal fossa, and the resulting hematoma is usually unsightly. A 20-year-old woman presented with massive edema followed by hematoma in the upper right jaw immediately after PSAN block administration, which subsequently spread to the oral mucosa. The patient did not report any complications during the anesthetic procedure. However, after the injection was administered, the patient experienced anesthetic sensations, which rapidly evolved to facial edema. There was mild pain, but without intraoral or extraoral bleeding. The patient was prescribed medicines and instructed to perform contrast therapy. Although hematomas and edema are rare, they are difficult to prevent. The choice of local anesthetic and appropriate application of the anesthetic technique can minimize their occurrence.

13.
Br J Clin Pharmacol ; 88(11): 4708-4723, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35723628

RESUMO

Knowledge about viral characteristics, mechanisms of entry into the host cell and multiplication/dissemination can help in the control and treatment of viral pathologies. Several nutritional factors linked to the host may favour viral multiplication and their control, may lead to new prophylactic alternatives and/or antiviral therapies. The objective of this review is to discuss the relationship between the amino acid L-lysine and the control of viral infections, aiming at a possible therapeutic property. This research used databases such as PubMed, Web of Science, Scielo, Medline and Google Scholar, as well as searching for references cited by journals. The time frame covered the period between 1964 and January 2022. The observed studies have shown that the usual antiviral therapies are not able to interfere with the viruses in their latent state; however, they can interfere with the adhesion and fusion of viral particles or the production of proteins, which play an important role in viral epidemiology and control, particularly in the initial moment and in reactivation. Lysine is an amino acid that can interfere mainly in the formation of capsid proteins and DNA by a competitive antagonism with amino acid arginine, which is an essential amino acid for some viruses, and also by promoting the increase of arginase, increasing the catabolism of arginine. Although there is evidence of the importance of L-lysine in viral control, more studies are needed, with a view to new antiviral therapies.


Assuntos
Lisina , Viroses , Aminoácidos/uso terapêutico , Antivirais/farmacologia , Antivirais/uso terapêutico , Arginase , Arginina/metabolismo , Arginina/uso terapêutico , Proteínas do Capsídeo , Humanos , Lisina/metabolismo , Lisina/uso terapêutico , Viroses/tratamento farmacológico , Viroses/prevenção & controle
14.
J. oral res. (Impresa) ; 11(1): 1-8, may. 11, 2022. tab
Artigo em Inglês | LILACS | ID: biblio-1399824

RESUMO

Introduction: The aim of this study was to assess the agreement between oral and maxillofacial radiologists (OMFR) and oral and maxillofacial surgeons (OMFS) for the detection of bifid mandibular canal (BMC) and accessory mental foramen (AMF) using cone-beam computed tomography (CBCT). Material and Methods: This retrospective study involved 22 examiners (11 OMFR and 11 OMFS) who independently assessed 30 CBCT volumes from patients (n = 60 hemi-mandibles) under preoperative radiographic evaluation for implant placement. The examiners scored the presence of BMC and AMF in each hemimandible. The interexaminer agreements were assessed using Fleiss' kappa statistics. Results: For intra-examiner agreement, 40% of the sample was reevaluated. The interexaminer agreement between OMFR and OMFS was slight (0.12) for the detection of BMC and fair (0.24) for AMF. The agreement among OMFR for detection of BMC was fair (0.22), and it was slight among OMFS (0.15). The agreement among OMFR for detection of AMF was substantial (0.61), and among OMFS it was fair (0.22). Agreements between OMFR and OMFS were slight for BMC and fair for AMF, independently of the years of experience. Intraexaminer agreement ranged from 60% to 90% among OMFR and from 55% to 90% among OMFS. Conclusion: A slight and a fair agreement between OMFR and OMFS was found for the detection of BMC and AMF, respectively. In general, OMFR obtained higher agreement among themselves, mainly for detection of AMF.


Introducción: El objetivo de este estudio fue evaluar la con-cordancia entre los radiólogos orales y maxilofaciales (ROMF) y los cirujanos orales y maxilofaciales (COMF) para la detección del canal mandibular bífido (CMB) y el foramen mentoniano accesorio (FMA) mediante tomografía computarizada de haz cónico. CBCT). Material y Métodos: Este estudio retrospectivo involucró a 22 examinadores (11 ROMF y 11 COMF) que evaluaron de forma independiente 30 volúmenes CBCT de pacientes (n = 60 hemimandíbulas) bajo evaluación radiográfica preoperatoria para la colocación de implantes. Los examinadores puntu-aron la presencia de CMB y FMA en cada hemimandíbula. Los acuerdos entre examinadores se evaluaron utilizando las estadísticas kappa de Fleiss. Resultados: Por concordancia intraexaminador se reeva-luó el 40% de la muestra. El acuerdo entre examinadores entre ROMF y COMF fue ligero (0,12) para la detección de CMB y regular (0,24) para FMA. La concordancia entre ROMF para la detección de CMB fue regular (0,22) y leve entre COMF (0,15). El acuerdo entre ROMF para la detección de FMA fue sustancial (0,61), y entre COMF fue justo (0,22). Los acuerdos entre ROMF y COMF fueron leves para CMB y justos para FMA, independientemente de los años de experiencia. La concordancia entre examinadores varió del 60 % al 90 % entre ROMF y del 55 % al 90 % entre COMF. Conclusión: Se encontró un acuerdo leve y justo entre ROMF y COMF para la detección de CMB y FMA, respec-tivamente. En general, se obtuvo mayor acuerdo entre ROMF, principalmente para la detección de FMA.


Assuntos
Humanos , Masculino , Feminino , Cirurgiões Bucomaxilofaciais , Radiologistas , Forame Mentual/diagnóstico por imagem , Canal Mandibular/diagnóstico por imagem , Brasil , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico , Variação Anatômica , Mandíbula/diagnóstico por imagem
15.
Clin Oral Investig ; 26(7): 4743-4752, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35267096

RESUMO

OBJECTIVES: To evaluate the influence of digital filters of intraoral radiographic systems on the diagnosis of simulated internal and external root resorptions and image quality. MATERIALS AND METHODS: Internal root resorption (IRR) and external root resorption (ERR) were simulated in 34 teeth. For image acquisition, two radiographic systems were used: Digora Toto and VistaScan. All filters available in these systems were applied. Three observers scored the detection of root resorptions in a 5-point scale. The noise and the contrast-to-noise ratio (CNR) were calculated. The area under ROC curve, sensitivity, specificity, and accuracy were obtained. One-way ANOVA with Tukey's post hoc tests compared the diagnostic values, noise, and CNR between the filters (α = 0.05). RESULTS: For ERR, there were no significant differences in diagnostic values between the filters tested for both systems. For IRR, Original and Noise Reduction filters presented higher sensitivity than the Sharpen2 filter for images from Digora Toto, with no differences between the other groups. For VistaScan, there were no significant differences of diagnostic values between the groups studied. Noise values differed among the filters of both systems. The CNR of the filters differed only for the bone region for Digora Toto, while for VistaScan, both tooth and bone regions differed. CONCLUSIONS: Despite promoting changes in pixel intensities and affecting the noise level of the radiographic images, the digital filters of Digora Toto and VistaScan systems do not affect the diagnosis of internal or external root resorptions. CLINICAL RELEVANCE: Digital filters are common tools in digital radiographic systems and may be used by the professional without impairment in root resorptions diagnosis.


Assuntos
Reabsorção da Raiz , Humanos , Curva ROC , Radiografia Dentária Digital/métodos , Reabsorção da Raiz/diagnóstico por imagem , Raiz Dentária
16.
Arq Bras Cir Dig ; 34(3): e1615, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35019127

RESUMO

BACKGROUND: Obesity and bariatric surgery may be related with mental and oral disorders. AIM: To evaluate the impact of bariatric surgery on anxiety, initial dental caries lesion and gingival bleeding in obese patients. METHODS: Eighty-nine patients were divided in two groups: Control Group (CG) - obese patients and Experimental Group (EG) - patients submitted to bariatric surgery. EG was analyzed before and 12 months after bariatric surgery; for the CG, was respected an interval of 12 months between the evaluations. International Caries Detection and Assessment System, Gingival Bleeding Index and Trace-State Anxiety Inventory were used. Medical profile, anthropometrics data, sociodemographic and behavioral variables were considered. RESULTS: There were no statistically significant differences between groups in evaluation times regarding to initial dental caries lesion and anxiety. However, the number of teeth with initial dental caries lesion (p=0.0033) and gingival bleeding (p<0.0001) increased significantly after bariatric surgery in EG. CONCLUSION: These results reinforce the need for multi-professional team follow-up, including dental care, for both obese and bariatric patients.


Assuntos
Cirurgia Bariátrica , Cárie Dentária , Ansiedade , Humanos , Obesidade , Estudos Prospectivos
18.
RGO (Porto Alegre) ; 70: e20220001, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1365286

RESUMO

ABSTRACT The aim of this study was to emphasize the importance of monitoring vital signs, especially blood pressure, during dental care. Through a narrative review, the changes in blood pressure that may occur during outpatient procedures and the measures to be taken were discussed. The available literature was consulted in databases (PubMed, Scielo, Web of Science and Google Scholar), complemented by the analysis of the bibliographic references included and updated until April 2021. The keywords were used: "Anamnesis", "Arterial Pressure", "Arterial Hypertension", "Hypertensive Crisis", "Risk factors", "Stroke", "Subclavian Theft Syndrome" and "Atherosclerosis". It was concluded that care should be applied to all patients, but mainly to those over 50, hypertensive or not, with hypercholesterolemia, diabetes, anxious and fearful. All vital signs must be monitored, including the pain score. The situations of anxiety, pain and fear are triggers for changes in blood pressure even in normotensive patients as in controlled hypertensive patients. The blood pressure measurement, in the first consultation, must be performed in both arms and repeated annually or whenever there is a change in the patient's health status. In all other consultations, blood pressure control, as well as the assessment of all vital signs, must be performed before, during, after the procedure and before discharge. In the face of any major change, it is necessary to assess the risk/benefit ratio of the continuity of the procedure, so that risks to patients are avoided or minimized, as well as for the necessary referrals to be made.


RESUMO O objetivo deste trabalho foi enfatizar a importância da monitorização dos sinais vitais, particularmente da pressão arterial durante o atendimento odontológico. Por meio de uma revisão narrativa foram discutidas as alterações pressóricas que podem ocorrer durante procedimentos ambulatoriais e as medidas a serem tomadas. A literatura disponível foi consultada em bancos de dados (PubMed, Scielo, Web of Science e Google Scholar), complementada analisando as referências bibliográficas incluídas e atualizada até Abril de 2021. Foram usadas as palavras-chave: Anamnese, Pressão Arterial, Hipertensão Arterial, Crise Hipertensiva, Fatores de Risco, Acidente Vascular Cerebral, Síndrome do Roubo da Subclávia e Aterosclerose. Foi concluído que os cuidados devem ser aplicados em todos os pacientes mas em especial naqueles com idades superiores a 50 anos, hipertensos ou não, com hipercolesterolemia, diabetes, ansiosos e medrosos. Todos os sinais vitais devem ser monitorados, dentre eles, o score de dor. As situações de ansiedade, dor e medo são gatilhos para alterações pressóricas tanto em pacientes normotensos como nos hipertensos controlados. A aferição da pressão arterial, já na primeira consulta, deve ser realizada em ambos os braços e repetida anualmente ou sempre que houver modificação no quadro de saúde do paciente. Em todas as demais consultas, o controle pressórico como também a avaliação de todos os sinais vitais, deve ser no pré-, trans-, pós-procedimento e antes da alta. Diante de qualquer alteração importante, a relação risco/benefício da continuidade do procedimento precisa ser avaliada, para que seja evitado ou minimizado os riscos aos pacientes bem como para realizar os encaminhamentos necessários.

19.
Pharmaceutics ; 13(5)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946622

RESUMO

Permeation assays are important for the development of topical formulations applied on buccal mucosa. Swine buccal and esophageal epithelia are usually used as barriers for these assays, while frozen epithelia have been used to optimize the experimental setup. However, there is no consensus on these methods. In transdermal studies, barrier integrity has been evaluated by measuring electrical resistance (ER) across the skin, which has been demonstrated to be a simple, fast, safe, and cost-effective method. Therefore, the aims here were to investigate whether ER might also be an effective method to evaluate buccal and esophageal epithelium mucosa integrity for in vitro permeation studies, and to establish a cut-off ER value for each epithelium mucosa model. We further investigated whether buccal epithelium could be substituted by esophageal epithelium in transbuccal permeation studies, and whether their permeability and integrity were affected by freezing at -20 °C for 3 weeks. Fresh and frozen swine buccal and esophageal epithelia were mounted in Franz diffusion cells and were then submitted to ER measurement. Permeation assays were performed using lidocaine hydrochloride as a hydrophilic drug model. ER was shown to be a reliable method for evaluating esophageal and buccal epithelia. The esophageal epithelium presented higher permeability compared to the buccal epithelium. For both epithelia, freezing and storage led to decreased electrical resistivity and increased permeability. We conclude that ER may be safely used to confirm tissue integrity when it is equal to or above 3 kΩ for fresh esophageal mucosa, but not for buccal epithelium mucosa. However, the use of esophageal epithelium in in vitro transmucosal studies could overestimate the absorption of hydrophilic drugs. In addition, fresh samples are recommended for these experiments, especially when hydrophilic drugs are involved.

20.
Braz Oral Res ; 35: e036, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33909858

RESUMO

Evaluating factors that may influence the nose dimensions and, therefore, contribute to the singularity of a person, is important for obtaining a precise facial reconstruction (FR) in forensic anthropology. Thus, the aim in this study was to evaluate the influence of sex, skeletal class, and facial type on nose dimensions of Brazilian individuals using cone-beam computed tomography (CBCT) scans. CBCT images of 54 males and 67 females were classified according to skeletal class (class I, II, or III) and facial type (brachycephalic, dolichocephalic and mesocephalic). Linear and angular measurements of the nose were performed using the CS 3D Imaging software. The measurements obtained for males and females were compared by one-way ANOVA. Two-way ANOVA was used to compare the measurements in the different skeletal classes and facial types. Significance level was set at 5%. All linear measurements were greater in males (p < 0.05); the angular measurements, however, did not differ between sexes (p > 0.05). Linear and angular measurements of class III males were significantly different from the other classes; the same was observed for the angular measurements in females (p < 0.05). Regarding facial types, some linear measurements were significantly greater in dolichocephalics males (p < 0.05). For females, there was no influence of facial type (p > 0.05), except for the nasal convexity angle. Nose dimensions differed in specific points among different skeletal classes and facial types, and there was sexual dimorphism in all linear nose dimensions. This information may be applicable for nose reconstructions, allowing more reliable FR.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Brasil , Tomografia Computadorizada de Feixe Cônico , Face/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Nariz/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...